Autoplay
Autocomplete
Previous Lesson
Complete and Continue
ASPEN OneLiner Training Course (February 18 - March 3, 2025)
Introduction
Logistics (8:26)
Course Instructors (3:01)
1 OneLiner User Interface
1.1 One-line diagram elements and navigation [Xu Zhang] (17:17)
1.2 Model building using keyboard, drag/drop, copy/paste [Xu Zhang] (13:32)
1.3 Data browser, DataWKS.bas PowerScrip tool [Xu Zhang] (16:33)
1.4 Keyboard accelerators, using on-line help [Xu Zhang] (11:07)
1.5 Exercise: Working with OneLiner user interface [Xu Zhang]
2 File and Data Management
2.1 File and data management [Thanh Nguyen] (48:51)
2.2 Case builder [Thanh Nguyen] (68:20)
2.3 Case management exercise
3 Network Modeling
3.1 Bus, Generator, Loads and Shunts [Sherman Chan] (19:17)
3.2 Lines and Mutuals [Sherman Chan] (26:32)
3.3 Transformers, Phase Shifters, etc [Sherman Chan] (37:02)
3.4 Wind, Solar Plants and Network Anomalies [Sherman Chan] (19:43)
4 Short Circuit Calculations
4.1 Classical faults [Sherman Chan] (27:11)
4.2 Simultaneous faults [Sherman Chan] (11:34)
4.3 Starting voltage assumptions and other fault simulation options [Sherman Chan] (15:16)
4.4 IBR model [Chris Weldy] (35:57)
4.5 Exercise: Fault simulation [Sherman Chan]
5 Misc Short Circuit Topics
5.1 Batch and Summary fault simulation [Thanh Nguyen] (25:10)
5.2 Ground current calculator [Thanh Nguyen] (7:23)
5.3 Voltage sag analysis & Boundary equivalent [Sherman Chan] (26:02)
5.4 Fault simulation script apps [Thanh Nguyen] (16:58)
5.5 Fault locator [Xu Zhang] (16:23)
6 Relay Modeling
6.1 Overcurrent relays, fuses and reclosers [Thanh Nguyen] (51:42)
6.2 Distance relays [Thanh Nguyen] (23:17)
6.3 Voltage and line differential relay [Thanh Nguyen] (17:26)
7 OverCurrent Relay Coordination
7.1 OC window including annotations and graphics and pasting pictures [Charles Henville] (26:29)
7.2 Transformer damage and inrush curves and custom curves [Charles Henville] (17:20)
7.3 Definition and specification of primary and backup pairs [Charles Henville] (11:16)
7.4 Curve shifting and reasons for it [Charles Henville] (14:04)
7.5 Primary and backup measure currents on different branches or at different voltages [Charles Henville] (12:39)
7.6 Primary and backup use different measuring principles [Charles Henville] (8:12)
7.7 Primary and backup across transformers with phase shifts [Charles Henville] (10:42)
7.8 Impact of mutual coupling on primary and backup coordination [Charles Henville] (20:18)
7.9 Stepped event analysis and application with overcurrent relays on three terminal lines [Charles Henville] (41:26)
7.10 Distribution coordination exercise [Charles Henville]
7.11 Transmission ground overcurrent relay coordination exercise (includes specification of primary and backup pairs) [Charles Henville]
8 Distance Relay coordination
8.1 DS window including annotations and graphics and TTY window [Charles Henville] (15:06)
8.2 Difference between apparent impedance on graphic and whether or not the relay operates [Charles Henville] (11:58)
8.3 Example setting distance relays on 30 bus example system [Charles Henville] (17:58)
8.4 Curve shifting and reasons for it showing effects of infeed [Charles Henville] (9:13)
8.5 Example showing impact of mutual coupling [Charles Henville] (8:55)
8.6 Stepped event analysis resolves apparent miscoordination due to outfeed [Charles Henville] (4:03)
8.7 Time distance window [Charles Henville] (12:07)
8.8 Transmission line distance relay coordination exercise including effect of mutual coupling) [Charles Henville]
9 Logic scheme application examples [Charles Henville]
9.1 Communications assisted transmission line protection [Charles Henville] (55:46)
9.2 Distributed energy resource (DER) example [Charles Henville] (24:06)
9.3 Logic scheme exercise [Charles Henville]
10 Automatic Relay Coordination Checking
10.1 Checking relay settings: minimum pickup, instantaneous and zone-2 reach [Sherman Chan] (21:53)
10.2 Checking relay coordination with stepped events [Sherman Chan] (18:31)
10.3 Checking relay coordination with primary/backup pairs [Sherman Chan] (10:27)
10.4 Relay coordination PowerScript apps [Thanh Nguyen] (21:04)
11 Misc. Relay Topics
11.1 Create relay test file [Xu Zhang] (14:55)
11.2 Arc Flash Calculator [Thanh Nguyen] (25:15)
11.3 Overcurrent curve library editor [Xu Zhang] (12:53)
11.4 Distance relay library editor [Xu Zhang] (8:52)
12 Advanced Topics
12.1 Breaker Rating Module [Thanh Nguyen] (46:02)
13 PRC compliance
13.1 PRC 023 [Sherman Chan] (12:45)
13.2 PRC 025 [Sherman Chan] (13:43)
13.3 PRC 026 [Thanh Nguyen] (24:13)
13.4 PRC 027 [Thanh Nguyen] (25:22)
14 External data source link
14.1 Relay Import Wizard [Thanh Nguyen] (37:29)
14.2 ASPEN relay DB [Thanh Nguyen] (35:59)
14.3 ASPEN Line Database [Thanh Nguyen] (20:34)
14.4 Mapping table [Xu Zhang] (12:28)
15 Automation and scripting
15.1 PowerScript [Thanh Nguyen] (73:54)
15.2 PowerCalc [Thanh Nguyen] (32:30)
15.3 Excel link [Thanh Nguyen] (6:12)
15.4 OlxAPI module [Thanh Nguyen] (59:10)
15.5 Exercise: Scripting
16 Installation and Setup
16.1 Program installation and setup [Thanh Nguyen] (22:26)
17. Additional Topics
17.1 Built-in client for the new OneLiner Enterprise Module (EDX) (41:24)
17.2 Course Evaluation
1.1 One-line diagram elements and navigation [Xu Zhang]
Lesson content locked
If you're already enrolled,
you'll need to login
.